The 30 Series is a wide range pressure calibrator that fits easily into your shirt pocket. Its internal sensors give you 0.05% of reading accuracy and resist damage from overpressure.
Wide pressure range can measure vacuum and pressure up to 5000 PSI (300 bar)
Indicates milliamps to calibrate transmitters
Ultra compact and light
Very easy to learn and use
Battery operated
Brings laboratory accuracy to outdoor field conditions
Applications
Deadweight tester replacement
Flow computer calibration
Gauge calibration
Pressure regulator adjustment
Pressure transmitter calibration
Included with every new 30 Series Digital Pressure Calibrator an A2LA accredited calibration certificate with test data recorded at 5 different temperatures - proving that it meets published specifications over the entire operating range. You won't get this kind of detailed report anywhere else!
Specifications
Specifications include all effects of linearity, hysteresis, repeatability, temperature, and stability for one year. Download brochure
Accuracy
0 to Full Scale: ±(0.05% of Reading + Floor Term*)
*Floor Term = 0.005% of FS or display resolution, whichever is greater.
Vacuum: ±(0.25% of Reading + Vacuum Floor Term*)
* Vacuum Floor Term (VFT):
For 16 and 36 PSI, VFT = 0.004 PSI
For 300 PSI, VFT = 0.01 PSI
For 1 or 2 bar, and 100 or 200 kPa, VFT = 0.03 kPa or 0.0003 bar
For 20 bar or 2000 kPa, VFT = 0.1 kPa or 0.001 bar
Vacuum operation is not specified for 600 PSI (40 bar/4000 kPa models and higher. However, all models can be safely connected to vacuum. (Not recommended for continuous use at high vacuum.)
Temperature Operating & Compensated: 0°C to 50°C (32°F to 122°F). Storage: -20°C to 70°C (-4°F to 158°F).
Electrical Range: 0 to 55 mA Resolution: 0.001 mA Accuracy: ±(0.025% of Reading + 0.001 mA) Percentage Conversion: 4 mA = 0.00%; 20mA = 100.00% or 10 mA = 0.00%; 50 mA = 100.00%
Intrinsic Safety
Other Certifications DNV classification certifies all materials, components and systems relevant to the safe operation and quality of ships.
Media Compatibility
Liquids and gases compatible with PTFE (Polytetrafluoroethylene) penetrated and anodized aluminum sensor manifold, 316 stainless steel (sensor), PTFE can be eliminated, if required, by specifying option SPSS, in which case aluminum manifold(s) will be replaced with stainless steel manifold(s).
Note: Over-range occurs at 110% of full scale, causing "HP Over" or "LP Over" to be displayed.
Standard factory setting is 1"H2O = 0.036126 PSI (density of water @ 4°C). Specify at time of order if you require a different density (e.g., for water @ 68°F, 1"H2O= 0.036063 PSI).
Power Battery: One 9V battery. Battery life: 90 hours typical (alkaline battery). Low battery indicator: Displayed battery icon.
Enclosure Description: Extruded Aluminum with sealed membrane keypad. Dimensions: 29mm (1.15") D x 70mm (2.75") W x 130mm (5.4") L Weight:Model 33: 400g (14.0 oz), Model 31: 342g (12.0 oz), Model 31(1500 PSI and above): 360g (13.0 oz)
Sensor
All welded stainless steel sensor
Pressure Ranges
Pressure Ranges
Pressure Units and Resolution
PSI
bar
kPa1
Over
pressure
PSI
kg/cm2
Inch Hg
inch H2O
mm Hg
cm H2O
mm H2O
kPa
MPa
mbar
bar
162
13 & 4
1004
6.5x
0.001
0.0001
0.001
0.01
0.01
1
0.01
0.1
0.00014
362
23 & 4
2004
3.0x
0.001
0.0001
0.001
0.01
0.01
1
0.01
0.1
0.00014
300
20
2000
2.0x
0.01
0.001
0.01
0.1
0.1
1
0.1
0.001
600
40
4000
2.0x
0.01
0.001
0.1
0.0001
0.001
1500
100
10000
2.0x
0.1
0.01
1
0.001
0.01
3000
200
20000
1.5x
0.1
0.01
1
0.001
0.01
5000
300
30000
1.5x
0.1
0.01
1
0.001
0.01
1- kPa versions are restricted to kPa, MPa, bar and/or millibar, depending on pressure range.
2 - PSI versions with ranges of 36 PSI and lower include all possible scales except bar.
3 - Bar versions with ranges of 2 bar and lower include all scales except inch Hg, cm H2O and MPa.
4 - Applies to bar and kPa version only.
Second Pressure Range
300 PSI
600 PSI
1.5K PSI
3K PSI
5K PSI
20 bar
40 bar
100 bar
200 bar
300 bar
2K kPa
4K kPa
10K kPa
20K kPA
30K kPa
First Pressure Range
16 PSI
1 bar
100 kPa
x
x
x
x
x
36 PSI
2 bar
200 kPa
x
x
x
x
x
300 PSI
20 bar
2K kPa
n/a
n/a
x
x
n/a
Model 33 calibrators have dual pressure sensors. This chart shows all of the sensor combinations.
Options
Part No.
-SPSS
Stainless Steel Manifolds
All high pressure sensors come with a stainless steel manifold. Some applications require that the second sensor on a 30 Series be stainless steel as well
Crystal Care
Crystal Care Program (US and Canada customers only) A 3-year full warranty program covering virtually any failure and an annual A2LA accredited calibration certificate with test data recorded at 5 different temperatures - proving that it meets published specifications over the entire operating range
Software
Part No.
ConFigM30
ConFigM30
Allows you to customize your calibrator by adding or disabling features
LabVIEW driver
LabVIEW driver
If using LabVIEW, the driver library implements the serial commands of the Model 30 and provides parsing of the streaming data output
FastCalXP
FastCalXP calibration software that allows you to do a 10 point up and down calibration in less than 3 minutes. See Demo
Accessories
Part No.
2490
Soft carrying case is included with every 30 Series calibrator. The clear plastic cover protects the keypad while allowing operation of all buttons